ASTM D6413

Standard Test Method Flame Resistance of Textiles (Vertical Test)

This is the defining Test Method for compliance with OSHA 1910.269 and one of the most commonly used tests on flame resistant fabrics.  Adopted from Federal Test Standard No. 191A, method 5903.1, the vertical flame test has been used for many years. 

  • The purpose of this test is to determine whether a fabric will continue to burn after the source of ignition is removed. 
  • A 12” specimen of fabric is suspended in an enclosed chamber (secured on three sides).   The cut edge of the fabric on the bottom is exposed to a controlled methane flame for 12 seconds. 
  • After exposure to the flame, afterflame, afterglow and char length are measured.  Five tests are performed and the results are averaged and reported as the test result.   
  • ASTM D6413 is used to determine a pass/fail criteria for ASTM F1506, which requires a maximum char length of 6 inches.  
  • Note: ASTM F1506 requires a maximum char length of 6 inches under this test method, whereas NFPA 2112 requires a maximum of 4 inches.  A 6-inch char length is more universally accepted as the maximum.

 The standard can be purchased and downloaded from the ASTM website at http://www.astm.org/Standards/D6413.htm.

 

 

 

ABOUT US

Our Story
Certified Woman-Owned (WBE)
Careers
News
Sustainability
Factory Store Williamsport,PA
Factory Store Midland, TX
WBENC_logo

 

 

 

  

INDUSTRIES WE SERVE

Electric Utilities
Gas Utilities
Electrical Maintenance
Chemical Manufacturing
Manufacturing
Refineries and Drilling
Nuclear Security
Rail
General Uniforms & Workwear

 

FR SAFETY LIBRARY

Products
Fabrics
Standards 
FAQs 
Industry Links
Videos & Blog
White Papers

 

 

CONTACT

Tyndale Sizing Chart
Assistance
800.356.3433
This email address is being protected from spambots. You need JavaScript enabled to view it.
Tyndale Facebook
Tyndale Twitter photo  thTyndale Blog icon